Features
•    Reliably handle a wide range of high-current applications with 2000 A AC + DC True RMS, 1400 A AC, and 2000 A DC
•    The large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors
•    CAT IV 600 V, CAT III 1000 V rating for added user protection
•    In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability
============================================================
Specifications
Electrical Specifications
Current measurement DC and AC 10 Hz to 100 Hz :
– Range : 40 A / 400 A / 2000 A / 1400 AC rms
– Resolution : 10 mA / 100 mA / 1 A
– Accuracy : A: 1.5% rdg + 15 digits, A: 1.5% rdg + 5 digits
– Trigger level for Inrush : 0.50 A / 5.0 A / 5 A
– Trigger level for Hz filter OFF : 2.50 A / 2.5 A / 8 A
– Trigger level for Hz filter ON : 0.50 A / 2.5 A / 8 A
Crest Factor (50/60 Hz) :
 – Range : 40 A / 400 A / 2000 A / 1400 AC rms
 – Crest Factor1 :
* 2 @ 33 A, 2.4 @ 27 A
* 2 @ 330 A, 2.4 @ 270 A
* 2 @ 1000 A, 2.4 @ 833 A
Current measurement AC 100.1 Hz to 1 kHz :
– Range : 40 A / 400 A / 2000 A; 1400 AC rms
– Resolution : 10 mA / 100 mA / 1 A
– Accuracy : 10 A: 3.5% rdg + 15 digits, 10 A: 3.5% rdg + 5 digits
– Trigger level for Inrush : 0.50 A / 5.0 A / 5 A
– Trigger level for Hz filter OFF : 2.50 A / 2.5 A / 8 A
– Trigger level for Hz filter ON : 0.50 A / 2.5 A / 8 A
Voltage measurement DC and AC 10 Hz to 100 Hz (600 V and 1000 V ranges have 10% over range to 660 V and 1100 V respectively.) :
– Range : 4 V / 40 V / 400 V / 600 V AC rms / 1000 VDC
– Resolution : 1 mV / 10 mV / 100 mV / 1 V
– Accuracy : 1% rdg + 10 digits, 1% rdg + 5 digits
– Trigger level for Hz filter OFF : 0.25 V / 6 V
– Trigger level for Hz filter ON : 0.25 V / 6 V
Voltage measurement AC 100.1 Hz to 1 kHz (600 V and 1000 V ranges have 10% over range to 660 V and 1100 V respectively.) :
– Range : 4 V / 40 V / 400 V / 600 V ac rms
– Resolution : 1 mV / 10 mV / 100 mV / 1 V
– Accuracy : 3% rdg + 10 digits, 3% rdg + 5 digits
– Trigger level for Hz filter OFF : 0.050 V / 0.25 V / 6 V
– Trigger level for Hz filter ON : 0.050 V / 0.25 V / 6 V
Ohms measurement :
– Range : 4 kΩ / 40 kΩ / 400 kΩ
– Resolution : 0.1 Ω / 1 Ω / 10 Ω / 100 Ω
– Accuracy : 1.5% + 5 digits
Continuity beeper : On at ≤ 30 Ω, Off at ≥ 100 Ω
Frequency measurement :
– Measurement range : 5.0 Hz to 1 kHz
– Resolution: 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz)
– Accuracy – 5.0 Hz to 100 Hz; 0.2% + 2 counts
– Accuracy – 100.1 Hz to 1 kHz : 0.5% + 5 counts
– Trigger level : Refer to current and voltage tables
General Specifications
Batteries : Six 1.5 V AA NEDA 15 A or IEC LR6
Battery life (with typical usage, backlight off) : 100 hours
Test leads : Rated to 1000 V
Weight : 814 kg
Jaw size     : 58 mm
Dimensions (L x W x D) : 300 x 98 x 52 mm
Safety rating : IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III
Included : C43 soft carrying case, 6 AA batteries, TL224 1.5 m silicone rubber test leads, TP2 test probes, AC285 alligator clips, User manual
===========================================================