Fluke 15B+ Digital Multimeter


Keterangan

Tanggal : 7 Juni 2022

Fluke 15B+ Digital Multimeter
============================================================
Features
•    600 V Cat III safety rating
•    50% bigger display with bright white backlight
•    Voltage, resistance, continuity, capacitance
•    Input terminal for ac and dc current measurements to 10 A current
•    Diode test, data hold
============================================================
Specifications
AC volts (40 Hz to 500Hz) :
– Range : 1000 V
– Resolution : 0.001 V
– Accuracy : 1.0% + 3
DC volts :
– Range : 1000 V
– Resolution : 0.001 V
– Accuracy : 0.5% + 3
AC millivolts :
– Range : 400 mV
– Resolution : 0.1 mV
– Accuracy : 3.0% + 3
DC millivolts :
– Range : 400 mV
– Resolution : 0.1 mV
– Accuracy : 1.0% + 10
Diode test :
– Range : 2V
– Resolution : 0.001 V
– Accuracy : 10%
Resistance (Ohms) :
– Range : 40 MΩ
– Resolution : 0.1 Ω
– Accuracy : 0.5% + 3
Capacitance :
– Range : 1000 μF
– Resolution : 0.01 nF
– Accuracy : 2% + 5
AC current μA (40 Hz to 400 Hz) :
– Range : 4000 μA
– Resolution : 0.1 μA
– Accuracy : 1.5% + 3
AC current mA (40 Hz to 400 Hz) :
– Range : 400 mA
– Resolution : 0.01 mA
– Accuracy : 1.5% + 3
DC current μA :
– Range : 4000 μA
– Resolution : 0.1 μA
– Accuracy : 1.5% + 3
DC current mA :
– Range : 400 mA
– Resolution : 0.01 mA
– Accuracy : 1.5% + 3
DC current A :
– Range : 10 A
– Resolution : 0.001 A
– Accuracy : 1.5% + 3
Backlight : Yes
AC volts :
– Overload protection : 1000 V
– Input impedance (Nominal) : >10 MΩ <100 pF
– Common mode rejection ratio : >60 dB at dc, 50 Hz or 60 Hz
AC millivolts :
– Overload protection : 400 mV
– Input impedance (Nominal) : >1MΩ, <100 pF
– Common mode rejection ratio : >80 dB at 50 Hz or 60 Hz
DC volts :
– Overload protection : 1000 V
– Input impedance (Nominal) : >10 MΩ <100 pF
– Common mode rejection ratio : >100 dB at dc, 50 Hz or 60 Hz
– Normal mode rejection ratio : >60 dB at 50 Hz or 60 Hz
DC millivolts :
– Overload protection : 400 mV
– Input impedance (Nominal) : >1MΩ, <100 pF
– Common mode rejection ratio : >80 dB at 50 Hz or 60 Hz
General specifications
Maximum voltage between any terminal and earth ground : 1000 V
Display (LCD) : 4000 counts, updates 3/sec
Battery type : 2 AA, NEDA 15A, IEC LR6
Battery life : 500 hours minimum (50 hours in LED Test mode without load. The hours with load depends on the type of LED under test.)
Temperature
– Operating : 0 °C to 40 °C
– Storage : -30 °C to 60 °C
Altitude : 2000 m, Storage : 12,000 m
Temperature coefficient : 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Fuse protection for current inputs : 440 mA, 1000 V Fast Fuse, Fluke specified part only. 11A, 1000V Fast Fuse, Fluke specified part only.
Size (H x W x L) : 183 x 91 x 49.5 mm
Weight : 455 g
IP rating : IP 40
Safety : IEC 61010-1, IEC61010-2-030 CAT III 600 V, CAT II 1000 V, Pollution Degree 2
Electromagnetic environment : IEC 61326-1: Portable
Includes : TL75 test leads with two caps, 2 AA batteries, User’s manual
===========================================================